Edge Device Operation in the People's Republic of China

Edge Device Operation in the People's Republic of China

Instructions for Service Technicians

Purpose of this Guide

This guide applies to Edge Devices that are already operating in the People’s Republic of China (PRC), or will be moved there. We are offering a specific endpoint for Port Unification within the PRC to provide superior connection quality and bandwidth.

On-site Requirements

Firewall Settings

Before migration or commissioning begins, the customer's IT department must ensure that the default required target addresses are accessible. In order to use the Port Unification endpoint within the PRC, an additional setting is required:

Endpoint

IP Address

Port

Note

Endpoint

IP Address

Port

Note

Portunification China

portunification-cn.symmedia-hub.com

443

Must be reachable from the customer network.

Important: As far as our experience goes, Edge Devices cannot be reliably operated in the PRC without using our specific Port Unification endpoint.
Please make sure that the customer's IT department has implemented all required firewall settings before the appointment.

Edge Device Prerequisites

In order to use Port Unification in the PRC, you need an Edge Device running OS version 25.09.4 or later.

If the Edge Device in question is not running the required OS version, it needs to be updated. Due to the suboptimal standard connection, it is recommended that you update the device via a USB flash drive. Instructions can be found here.

Step-by-step Process

The process described below is a current workaround. In the future, these settings will be configurable directly from the portal. 

  1. Create a support ticket on the symmedia Helpdesk. (https://symmedia.atlassian.net/servicedesk/customer/portals)

  2. Include the device serial number and location in the ticket.

  3. symmedia Support will make the necessary URL adjustments. This can be done either locally via a USB stick or manually via GraphQL.

ChatGPT Image 17. Juni 2026, 09_08_37.png

Final Checks

  • The Edge Device is visible in symmedia Hub and displayed as ONLINE.

  • The Edge Device uses the designated China endpoint.

    • Check in the Cockpit on the Edge Device:

      • Open Cockpit, navigate to Services → PTW

      • Check the PTW Service Logs for the portunification URL, i.e. portunification-cn.symmedia-hub.com

  • Downloads and updates run without interruption.

  • The Operator was informed that the firewall approvals must remain active.

In Case of Error

Do not make independent changes if there are deviations, unreachable target addresses, or unclear status messages. Document the issue and contact symmedia Support with the device serial number (S/N), location, time, and error message: 

https://symmedia.atlassian.net/servicedesk/customer/portals